5 Commissioning
5.1 Display and control keys
Fig. 4: Key function
The keys are double-assigned and have the following functions depending
on the version ordered (see ordering key):
Basic function:
1
Incremental measurement key
2
Change to calibration value input mode
3
Reset key
Calibration mode:
1
Decrease value
2
Save and return to basic function
3
Increase value
4
Battery symbol, visible with low battery voltage. Replace battery (see
chapter 6).
5
Incremental measurement symbol, visible with active incremental
measurement.
6
Calibration value input symbol, visible with active calibration value
input.