The programmable factor is calculated as follows: FAc = total display range
[1/10°] / circumference [1/100mm]
3600 / 94248 = 0.03820
Designation Display Progr. value
Resolution rES FrEE
Calculation factor FAc 0.03820
Decimal point dP 0.0
Reference value rEF 00000.0
Oset oFS 00000.0
Counting direction dir uP
Switch-o method Auto on
Switch-o time PEriod 0.5
Last value memory rSto oFF
Delayed switch-o 4_oFF oFF
Reset function enable F_Abs on
Increm. meas. function enable F_rEL oFF
Reference value change enable F_rEF oFF
Language LAn E