Appendix: Parameter list English
MA503/1-S · Date 05.09.2016 · Art. No. 80994 · Mod. status 151/16
19
10 Appendix: Parameter list
Display Designation / value range Standard
programming
your
programming
rES Resolution (mm, In=inch): 1, 0.1, 0.05, 0.01,
In 0.01, In 0.001, FrEE, 1/16in, 1/32in; 1/64in
0.1
FAc Calculation factor (only if resolution has been
programmed to "FrEE"): 0.00000 ... 9.99999
0.00000
dP Decimal point (only if resolution has been pro-
grammed to "FrEE"): 0. to 0.000
0.00
rEF Reference value: -99999 ... (+)99999 00000.0
oFS Oset value: -99999 ... (+)99999 00000.0
dir Counting direction: uP, dn uP
Auto Switch-o method: on, oFF oFF
PEriod Switch-o time (in hours) (only for switch-o
methods 'on'): 0.2; 0.5; 1.0; 2.0; 4.0; 8.0
0.2
rSto Last value memory: on, oFF oFF
4_oFF Delayed switch-o: on, oFF oFF
4_Abs Delayed reset function: on, oFF oFF
F_AbS Reset function enable: on, oFF on
F_rEL Increm. meas. function enable: on, oFF oFF
F_rEF Reference value change enable: on, oFF oFF
F_oFS Oset correction enable: on, oFF oFF
LAn Language: d, E d