17"
"
“Cata” / “Ana” modes:
• All jewelleries must be removed.
• Place the contact electrode covered with wet gauze, under the shoulder, when working
around face area or upper body or under the thighs when working on lower body.
• Apply a layer of Sensibilis Lotion / Sensiblis Gel (post-depilation soothing gel for
“Cata” mode and pre-depilation lotion for “Ana” mode).
• Use the roller electrode over the treated area for 3 minutes. (Never use metallic roller on
bare skin).
• Remove gel and rinse the skin.
• To prevent electrode deterioration, remove gel residues from roller electrode.
• Use bactericidal wipes to disinfect roller.
Recommended intensity settings for “Cata” mode:
• For Face: 0.35 mA to 1.00 mA
• For Body: 1.00 mA to 2.00 mA
" Treatment should be comfortable and soothing.
" Client should feel very light tingling or cooling sensation.
" A tingling may also be felt under the contact electrode (make sure the electrode is
covered with wet gauze).
Recommended intensity settings for “Ana” mode:
• For Face: 0.30 mA to 1.00 mA
• For Body: 1.00 mA to 2.00 mA
" Note: This phase should NEVER be used after electrolysis treatments.
" Client should only feel slight tingling. Lower intensity if client is uncomfortable.
" Treatment should never cause any discomfort.
" A tingling may also be felt under the contact electrode (make sure the electrode is
covered with wet gauze).