SLE 280 A2
42 
GB
MT
Tube drainage
In very damp rooms, it is often more appropriate for the water not to collect in
the water tank
5
, but for it to be drained directly by means of a tube.You can
use the supplied hose
25
or the EU garden hose adapter
26
to set up a perma-
nent drainage system.
CAUTION
When draining via the hose, the appliance runs continuously. During hose
drainage, ensure that the hose is not kinked and that it runs downwards
over its entire length as the appliance does not have a pump for drainage.
Check all connections in the system regularly for watertightness.
Unscrew the closure
13
on the rear of the appliance (see fig. 2).
Either connect the supplied hose
25
to the outlet
14
or screw the EU garden
hose adapter
26
to the outlet
14
(see figs. 3 + 4).
If you are using the EU garden hose adapter
26
, screw a garden hose onto
the EU garden hose adapter
26
(see fig. 4).
Fig. 2 Fig. 3 Fig. 4
CAUTION
Screw the EU garden hose adapter
26
hand-tight only. Do not use a
wrench as this could damage the EU garden hose adapter
26
.
NOTE
Ensure that the seal of the EU garden hose adapter
26
is always inserted
(the seal is already fitted on delivery).
Depending on the garden hose system you use, you may need an additional
adapter. These are available from specialist stores.