4. Technical specifications
Mains voltage: 85 to 264 V
Frequency: 47 – 63 Hz.
ECM 30N (P) ECM 60N (P)
Max. power consumption: 240W 240W
Fuse (back): 3.15 AT 3.15 AT
Output voltage: 0 – 30 kV DC 0 – 60 kV DC
Max. output current: 5 mA 2.5 mA
Maximum power output: 150 W 150 W
Cooling convection convection
Polarity: N = negative / P = positive
Short-circuit protection: output electronically protected at max. output current
Mains connection: using Euro connector IEC-320
Accuracy of display: 1 % of max. value ± 2 digits
Voltage stabilisation: 2 % of maximum output voltage at mains voltage
fluctuations between 85 and 264 V.
Load stabilisation: 2 % of maximum output voltage at load fluctuations
between 0 and max.
Output voltage: can be set between 0 kV and max. output voltage
Ripple, peak-peak: 5 % of maximum output voltage at maximum load
Remote on/off: 0V = off, 12 V = on (typical)
Control voltage specifications:
10 VDC, 10 mA min
25 VDC, 25mA max
Internal power supply: 12 VDC(+/- 20%), 20mA (U
ripple
= 0.5V
tt
Max)
for remote on/off and external overload signalling, if
necessary
Ambient temperature: 0 – 40 °C
Operating environment: vibration-free installation
Input/output connectors 4x HV output
1x I/O Sub-D 25-pin
Options: Remote control functions:
- switching on/off at high voltage
- output voltage read out
- input current read out
- output voltage control
- overload indication (maximum load 50VDC, 50mA)
5. Installation
5.1. Checks
- Check that the generator is undamaged and that you have received the correct version.
- Check that the details on the packing slip correspond with the details shown on the product
received.
If you have any problems and/or if in doubt:
Please contact SIMCO or your regional agent.
97.52.09.0230 ECM 30 /ECM 60 03/04
27