10. Faults
Problem Cause Remedy
No output voltage
Display off
Mains voltage < 85V AC Restore mains voltage
Fuse at the rear of the unit
is defective
Replace fuse
High voltage generator
defective
Send generator for repair
No output voltage
Display on
A setpoint has not been
given
(note, in [(UN)LOCKED]
position this comes from
the [
] / [ ] keys and in
[REMOTE] via the Sub-D
connector)
Give setpoint
Remote on/off dipswitch
has been switched on, but
signal is not sent to switch
the generator on
Press the [RUN] key to
switch the generator on
Switch off remote on/off
dipswitch
or send signal to the Sub-D
connector to switch the
generator on
High voltage generator
defective
Send generator for repair
[OVERLOAD] led lights up Sparking or short-circuit in
connected equipment
Check connected equipment
Generator overloaded Reduce setpoint
Increase distance between
charging bar / electrode and
material
Table 1 Faults
11. Repair
Warning:
- When carrying out work on the equipment: de-energise the equipment.
- Repairs must be made by a skilled electrical engineer.
- When opening the equipment, you may come into contact with parts under dangerous
voltages.
SIMCO recommends that you return the generator if repairs are required.
Pack it properly and clearly state the reason for return.
97.52.09.0230 ECM 30 /ECM 60 03/04