9752090250 ECM Lite 11/03
24
4. Technical specifications
Mains voltage: 90 – 130 VAC or 207 - 253 VAC
Frequency: 47 - 63 Hz.
ECM - N (P) Lite
Max. power input: 48 W
Fuse (rear): 630 mAT
Output voltage: 0 - 20 kV DC
Max. output current: 0.7 mA
Maximum power output: 14 W
Cooling: convection
Polarity: N = negative/P = positive
Short-circuit protection: output electronically protected at max. output current
Mains connection: Euro connector IEC-320
Accuracy of display: 1 % of max. value ± 2 digits
Voltage stabilisation: 2 % of max. output voltage with a mains voltage of
90 – 130 VAC / 207 - 253 VAC
Load stabilisation: 2 % of maximum output voltage at load fluctuations
between 0 and max.
Output voltage: can be set between 0 kV and max. output voltage
Ripple, peak-peak: 10 % of maximum output voltage at maximum load
Remote on/off: 0V = off, 12 V = on (typical)
Control voltage specifications:
10 VDC, 10 mA min.
25 VDC, 25mA max.
Internal power supply: 12 VDC (+/- 20%), 20mA (U
ripple
= 0.5V
tt
max.)
for remote on/off and external overload signalling, if
necessary
Ambient temperature: 0 - 40 °C
Operating environment: vibration-free installation
Input/output connectors: 4x HV output
1x I/O Sub-D 25-pin
Options: Remote control functions:
- switching high voltage on/off
- output voltage regulation
5. Installation
5.1. Checks
- Check that the generator is undamaged and that you have received the correct model.
- Check that the details on the packing slip correspond with the details shown on the product
received.
If you have any problems and/or if in doubt:
Please contact SIMCO or your regional agent.