Dipswitch Settings (Rear-panel)
Switch no. 1 2 3 4 5 6 7 8 Comment Application
Default
settings
Off Off Off Off On Off Off Off
Disable Off Remote
on/off
Enable On Potential free
switching
PLC controlled on/off
with presetted setpoint
0-5V Off 5 V = 100 % output
current
Current
Readout
0-10V On 10 V = 100 % out-
put current
Remote current meter
0-5V Off 5 V = 100 % output
voltage
Voltage
Readout
0-10V On 10 V = 100 % out-
put voltage
Remote voltage meter
0-5V Off Off Off 5 V = 100 % output
voltage
0-10V Off On Off 10 V = 100 % out-
put voltage
0-20mA On Off Off 20 mA = 100 %
output voltage
External
Setpoint
Source
4-20mA On Off On 20 mA = 100 %
output voltage
Analogue (PLC) con-
trolled output voltage
Normal Off Real time voltage
readout
Internal
Readout
Streched On 0,7 s readout of last
output voltage
short pulsed high volt-
age display reading
Normal Off Real time overload
readout
External
Overload
Streched On Real time overload
readout + 0,5 s
Easier detection
Waarschuwing:
− Voor het instellen van de dipswitches, generator spanningsloos
maken.
Warning:
− Before setting the dipswitches: De-energise the equipment.
Warnung:
− Vorab dass einstellen den DIP-Schalter, das Gerät spannungslos machen.
Attention:
−
Avant tout réglage du microinterrupteur, mettre le générateur hors tension.
Bijlage / encl. 1
97.52.09.0230 ECM 30 /ECM 60 03/04
49