SIM7000 Series_AT Command Manual_V1.03 88 2018-05-08
Time
Reference
5.2.8 AT+CSCLK Configure Slow Clock
AT+CSCLK Configure Slow Clock
Test Command
AT+CSCLK=?
Response
+CSCLK: (list of supported <n>s)
OK
Parameter
See Write Command
Read Command
AT+CSCLK?
Response
+CSCLK: <n>
OK
Parameter
See Write Command
Write Command
AT+CSCLK=<n
>
Response
OK
ERROR
Parameter
<n> 0 Disable slow clock, module will not enter sleep mode.
1 Enable slow clock, it is controlled by DTR. When DTR is
high, module can enter sleep mode. When DTR changes to low
level, module can quit sleep mode.
Parameter Saving
Mode
AUTO_SAVE
Max Response
Time
-
Reference Note
5.2.9 AT+CCID Show ICCID
AT+CCID Show ICCID
Test Command
AT+CCID=?
Response
OK
SIMCOM COMFIDENTIAL FILE