Rendimenti caldaie murali a gas
MODELLO Potenza termica Portata termica Tipo di Marcatura Rendimento utili misurati Rend. minimo di comb.
kW kW caldaia stelle 100% - 30% %
PLANET - FORMAT 25 OF C 23,3 25,8 BT 2 90,3 - 89,7 92,73
PLANET - FORMAT 30 OF C 28,6 31,6 BT 2 90,4 - 91,3 92,91
PLANET 25 BFT TS 25,6 27,5 BT 3 93,2 - 91,2 92,82
PLANET AQUAQUICK 25 TS - 25 PLUS 25,6 27,5 BT 3 93,2 - 91,2 92,82
PLANET AQUAQUICK 30 TS - 30 PLUS 30,4 32,5 BT 3 93,6 - 92,7 92,97
PLANET Low NOx 25 BF 23,2 25,0 ST 3 92,8 - 90,7 92,73
PLANET Low NOx 30 BF 27,9 30,0 ST 3 93,1 - 92,4 92,89
PLANET 25/60 BF 25,0 26,7 ST 3 93,5 - 92,0 92,80
PLANET 30/60 BF 29,5 31,6 ST 3 93,5 - 92,0 92,94
PLANET DEWY 25 BF - 25 BFT 24,0 24,9 CN 4 96,6 - 106,2 92,76
PLANET DEWY 30 BF 29,3 30,0 CN 4 97,7 - 106,6 92,93
PLANET DEWY 30 BFR 28,3 29,0 CN 4 97,7 - 106,6 92,90
PLANET DEWY 60 BFR 56,6 58,0 CN 4 97,5 - 109,8 93,51
PLANET DEWY 100 BFR 94,2 96,6 CN 4 97,5 - 109,0 93,95
PLANET DEWY 30/50 BF 29,2 30,0 CN 4 97,2 - 106,7 92,93
OPEN 25 BF TS2 23,8 25,5 BT 3 93,3 - 93,0 92,75
OPEN 30 BF TS2 30,8 33,0 BT 3 93,3 - 93,0 92,98
FORMAT 25 BF TS 25,6 27,5 BT 3 93,2 - 91,2 92,82
FORMAT 30 BF TS 30,4 32,5 BT 3 93,6 - 92,7 92,97
FORMAT 25/60 OF 23,2 25,8 BT 2 90,3 - 90,3 92,73
FORMAT 25/60 BF 25,0 26,7 ST 3 93,5 - 92,0 92,80
FORMAT 30/60 BF 29,5 31,6 ST 3 93,5 - 92,0 92,94
FORMAT.zip 5 25 OF - 25 OF ES 23,5 25,8 BT 2 91,2 - 91,1 92,74
FORMAT.zip 5 25 BF TS 23,7 25,5 BT 3 93,1 - 91,2 92,75
FORMAT.zip 30 OF S - 30 OF ES 28,8 31,6 BT 2 91,1 - 90,0 92,92
FORMAT.zip 25 BF TS - 25 BF TSA - 25 Solar
23,7 25,5 BT 3 93,1 - 91,2 92,75
FORMAT.zip 30 BF TS - 30 Solar 28,0 30,0 BT 3 93,6 - 92,8 92,89
FORMAT.zip 35 BF TS 32,4 34,8 BT 3 93,2 - 92,5 93,02
FORMAT.zip 25 PC 24,7 25,5 CN 4 96,9 - 103,0 92,79
FORMAT.zip 30 PC 29,1 30,0 CN 4 96,9 - 102,7 92,93
FORMAT.zip 35 PC 33,5 34,8 CN 4 96,3 - 101,5 93,05
OPEN.zip 25 BF TS 23,7 25,5 BT 3 93,1 - 91,2 92,75
OPEN.zip 30 BF TS 28,0 30,0 BT 3 93,6 - 92,8 92,89
OPEN.zip 25 BF TS2 - 6 25 BF 23,8 25,5 BT 3 93,3 - 93,0 92,75
OPEN.zip 30 BF TS2 - 6 30 BF 30,8 33,0 BT 3 93,3 - 93,0 92,98
FORMAT DEWY.zip 25 BF - 25 Solar 22,7 23,3 CN 4 97,5 - 109,2 92,71
FORMAT DEWY.zip 30 BF - 30 Solar 27,3 27,9 CN 4 97,9 - 110,4 92,87
OPEN DEWY.zip 25 BF - 25/40 24,5 25,0 CN 4 99,0 - 109,0 92,78
METROPOLIS - PRAKTICA 25 OF 23,7 25,8 BT 2 91,9 - 91,0 92,75
METROPOLIS - PRAKTICA 30 OF 28,8 31,6 BT 2 91,1 - 91,0 92,92
METROPOLIS - PRAKTICA 25 BF 23,8 25,5 BT 3 93,5 - 93,1 92,75
METROPOLIS - PRAKTICA 30 BF 30,8 33,0 BT 3 93,5 - 93,3 92,98
METROPOLIS DGT - PRAKTICA DGT 25 OF 22,8 25,0 BT 2 91,2 - 89,8 92,72
METROPOLIS DGT - PRAKTICA DGT 25 BF 23,7 25,5 BT 3 93,0 - 91,0 92,75
METROPOLIS DGT - PRAKTICA DGT 30 BF 28,0 30,0 BT 3 93,3 - 91,0 92,89
METROPOLIS DGT HE 25
METROPOLIS DGT HE 30
METROPOLIS DGT HE 35
METROPOLIS DGT HE 12T
METROPOLIS DGT HE 25T
METROPOLIS DGT HE 35/40
MURELLE 25 OFT - 25 OF - 25/55 OF 23,0 25,5 BT 2 90,0 - 89,5 92,72
MURELLE 30 OF 27,0 30,0 BT 2 90,0 - 89,5 92,86
MURELLE 20 BFT 19,8 21,3 BT 3 93,0 - 92,0 92,59
MURELLE 25 BFT - 25 BF 23,7 25,5 BT 3 93,0 - 92,0 92,75
MURELLE 30 BF 28,0 30,0 BT 3 93,3 - 92,0 92,89
MURELLE 35 BF 32,4 34,8 BT 3 93,1 - 92,0 93,02
MURELLE 25/55 BF 25,1 27,0 BT 3 93,0 - 91,5 92,80
MURELLE 30/55 BF 29,8 32,0 BT 3 93,0 - 91,5 92,95
MURELLE HE 12 BFT 11,7 12,0 CN 4 97,5 - 107,0 92,14
MURELLE HE 20 BFT 19,0 19,5 CN 4 97,5 - 107.0 92,56
MURELLE HE 25 BFT - 25 BF - 25/55 BF 23,9 24,5 CN 4 97,5 - 107,0 92,76
MURELLE HE 30 BFT - 30 BF - 30/55 BF 28,9 29,5 CN 4 98,0 - 107,0 92,92
MURELLE HE 35 BFT - 35 BF - BU 35 BFT - BU 35 BF
34,1 34,8 CN 4 98,0 - 107,0 93,07
NOTA: I rendimenti utili misurati sono riferiti ai tipi di caldaia (ST= standard, BT= bassa temperatura, CN= condensazione) richiesti dal DPR 660.
Il rendimento minimo di combustione in opera è quello richiesto dal DPR 311.