The 4008 supports up to four annunciator options
including:
Door Mounted 24 LED Annunciator
4610-9111 Remote LED/Switch Annunciators
4606-9101 Remote LCD Annunciators
Annunciators communicate at a rate of 9600 baud with
power supplied by separate wiring.
4610-9111 LED Annunciator Features:
16 LEDs with programmable functions and dedicated
LEDs for Alarm Silenced, Lost Communications,
Trouble, and Power-on
Keyswitch access controlled switches for
Acknowledge, Alarm Silence, Reset, and Lamp Test
Local tone-alert
4610-9111 LED/Switch Annunciator
4606-9101 LCD Annunciator Features:
LCD readout with two lines of 40 characters each and
LED backlighting
Wide viewing angle, super-twist design
Keyswitch access controlled
Control switches and status LEDs for:
Alarm, supervisory, or trouble acknowledge
Alarm silence and System Reset
Three programmable LED indicators:
Two LEDs are selectable as red or yellow
One LED is selectable as green or yellow
With provisions for custom labeling
4606-9101 LCD Annunciator
4 S4008-0001-8 8/2012
Detector Heads and Addressable Bases (refer to page 3 for 4008 detector/sensor terminology)
Model Detector Head Type Compatible Addressable Base Data Sheet
4098-9714
4098-9733
Photoelectric
Heat, 135° F (57° C)
4098-9792, Standard detector base
S4098-0019
4098-9789, Base for remote LED or relay
4098-9791, Features of 4098-9789 and remote supervised relay
4098-9794, Sounder base S4098-0028
4098-9793, IDNet Isolator base S4098-0025
4098-9754 Photo and Heat
4098-9795, Dual address sounder base
NOTE: These bases require
two addresses
S4098-0033
4098-9796, Dual address standard base
Duct Detection
Model Description Data Sheet
4098-9755 Addressable Duct Detector Housing with 4098-9714 detector, no relay control
S4098-0030
4098-9756 Addressable Duct Detector Housing with 4098-9714 detector, with remote relay control
Addressable Devices
Model and Description Data Sheet Model and Description Data Sheet Model and Description Data Sheet
4090-9001 Supervised IAM
S4090-0001
4090-9101 CL B ZAM
S4090-0003
4090-9007 Signal IAM S4090-0010
4090-9051 Supervised IAM 4090-9106 CL A ZAM 4099-9001, 4099-9002,
& 4099-9003 Manual
Stations
S4099-0001
4090-9002 Relay IAM S4090-0002 4090-9116 IDNet Isolator S4090-0005
Compatible System Expansion Panels
Model Type Description Data Sheet
4003 Series Voice Control Panel
Provides a remote voice control panel with on-board NACs, internal
microphone, and remote microphone input
S4003-0002
4009 Series Remote NAC Extender
Provides remote NACs; includes power supply and battery charger;
4 extenders max/NAC; 4008 uses NAC output to provide control
S4009-0002
Note: Contact your local Simplex Product Supplier for additional compatible peripherals.
Fire Alarm Annunciator
ACK
RESET
ALARM
SILENCE
LAMP
TEST
ALARM
SILENCED
LOST COM
TROUBLE
POWER
CONTROL
ENABLE
Compatible Simplex Peripherals (see specifications on page 5 for notification appliances)
Remote Annunciator Options