Features 
 
Standard features: 
•  80 Character, alphanumeric LCD readout with wide 
viewing angle 
•  Eight, Class B Initiating Device Circuits (IDCs)  
•  Four, Class B Notification Appliance Circuits (NACs)  
•  4 A power supply/battery charger 
•  Power-limited design 
•  Pluggable terminal blocks 
•  Internal DACT is included on UL listed models; 
available separately as required for ULC listed models 
Simplex
®
 system accessory compatibility: 
•  4602 Series Remote Control Unit (RCU) and Status 
Command Unit (SCU), two-wire serial 
communications 
•  4601 Series Annunciators 
•  4003 Voice Control Panels 
•  4009 NAC Power Extenders 
Software features: 
•  Menu-driven programming 
•  On-site programmable custom labels 
•  Four operator access levels 
•  Historical event logs 
•  Circuit selectable alarm verification 
•  WALKTEST™ one-person system testing** 
•  Selectable active status reminder 
Optional expansion: 
•  Two circuit IDC, two circuit NAC/relay
†
 
•  Four circuit NAC/relay
†
 
•  Four circuit IDC (low current and high current 
versions) 
•  Four circuit Class A NAC or IDC zone conversion 
•  Eight circuit I/O module 
•  Remote station/city connection 
•  Additional 5 A power supply 
UL Listed to Standard 864 
 
 
*   Refer to page 6 for additional ULC listing information. This product has been approved by 
the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California 
Health and Safety Code. See CSFM Listing 7165-0026:212 for allowable values and/or 
conditions concerning material presented in this document. It is subject to 
re-examination, revision, and possible cancellation. Accepted for use – City of New York 
Department of Buildings – MEA35-93E. See page 7 for ULC designations. Additional 
listings may be applicable; contact your local Simplex product supplier for the latest 
status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco 
Safety Products Westminster. 
 
CAUTION
DISCONNECT
BATTERY  AND
A. C.  POWER
BEFORE
SERVICING
ALARM
ACK
SUPV
ACK
TROUBLE
ACK
ALARM
SILENCE
SYSTEM
RESET
FIRE
ALARM
SYSTEM
SUPERVISO RY
SYSTEM
TROUBLE
ALARM
SILENCED
AC
POWER
 
Model 4005 Fire Alarm Control Panel 
 
 
Introduction 
 
For areas requiring eight to thirty-six IDC zones, Simplex 
4005 series fire alarm control panels provide flexible 
initiating circuit monitoring, extensive programmable 
control capability, and LCD annunciated circuit-specific 
custom labels. Surface mount components, efficient 
microprocessor programming, and easy-to-use control 
panel operation combine to provide an extensive feature 
list in a compact, “installation friendly” package. 
Panel status and circuit information is efficiently 
indicated by an alphanumeric LCD readout featuring two 
lines of 40 characters each. The panel control switches are 
clearly marked for intuitive operation. Programming of 
the selectable features is performed by using the display 
and the panel control switches while in the programming 
mode. 
Applications 
 
The 4005 series fire alarm control panel provides 
protection for a wide variety of mid-size facilities in the 
following fields: Educational, Health Care, Business, 
Storage, Hospitality, Residential, and General Assembly. 
Its modular design allows IDCs and NACs to be 
incremented in groups of two or four to satisfy circuit 
requirements without specifying excess capacity. If the 
system expands, then additional “snap-in-place” modules 
can be easily installed on-site. 
 
** WALKTEST performance testing is protected under US Patent No. 4,725,818. 
†  NACs may be individually configured for dry contact relay operation. 
NOTE:  Contact your local Simplex product supplier for fire alarm control panels suitable for 
Release Control applications. 
 
 
LifeAlarm
®
 Fire Alarm Control Panels
 
UL, ULC, CSFM Listed; FM Approved;   4005 Series Fire Alarm Control Panels  
MEA (NYC) Acceptance*  Providing 8 to 36 IDCs and 4 NACs 