Simrad RI35 Mk2 Rudder Angle Indicator
8 20220919D
Connection to older revision J3XX Junction
units
Figure 3-5 and Figure 3-6 is only valid for J3XX Junction units that
contains Main PCB revision D or older (A, B, C).
The interconnection cables are screened, and the screen should be
grounded in the autopilot junction unit.
Note ! If the J3XX junction unit has 24V supply (Vbat), the RI35 Mk2 Limiter
(part no. 22084990) must be connected to RF+ as shown in Figure
3-5.
*
* Non polarized (colour independant)
JUNCTION UNIT
MAIN PCB
Rudder
Feedb.
RF +
RF
FREQ SUPPLYCURR
RF300
RUDDER FEEDBACK
UNIT
RI35 Mk2
RUDDER ANGLE
INDICATOR
RI35 Mk2
RUDDER ANGLE
INDICATOR
*
*
*
FREQ SUPPLYCURR
*
Vbat+
DATABOX
(NMEA Input1)
NMEA NMEA
GND
Figure 3-5 RI35 Mk2 - J3XX (old) Wiring diagram
Note!
*
Note!
24V only
Rudder
Feedb.
RF +
RF
*