Figure 3-6 RI35 Mk2-J3XX (old), independent function of autopilot
Note ! In order to use the indicator when the autopilot is switched off, the
RI35 Mk2 Limiter must be connected as shown.
Connection to J45A/J45S Junction units
Note ! When the RF45X Rudder Feedback Unit is connected to J45A or J45S
junction units, the S1 plug-in strap on the RF45X PCB must be set to
position “AP45”.
* Non polarized (colour independant)
J45A JUNCTION UNIT
RF45X
RUDDER FEEDBACK
UNIT
12 11 10
GND
RUDDER FB I/P
+OUT
BLUE
GREEN
RED
*
FREQ SUPPLYCURR
RI35 Mk2
RUDDER ANGLE
INDICATOR
SUPPLY VOLTAGE 12/24V
RI35 Mk2
RUDDER ANGLE
INDICATOR
FREQ SUPPLY
CURR
*
NMEANMEA
Figure 3-7 RI35 Mk2 - J45A Wiring diagram
Note ! Autopilot supply and Indicator supply must have common GND.