Simrad RI35 Mk2 - Connection to J101 A;J200 S Junction Units

Simrad RI35 Mk2
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Simrad RI35 Mk2 Rudder Angle Indicator
10 20220919D
* Non polarized (colour independant)
J45S JUNCTION UNIT
RF45X
RUDDER FEEDBACK
UNIT
12 11 10
GND
RUDDER FB I/P
+OUT
BLUE
GREEN
RED
*
FREQ SUPPLYCURR
RI35 Mk2
RUDDER ANGLE
INDICATOR
SUPPLY VOLTAGE 12/24V
RI35 Mk2
RUDDER ANGLE
INDICATOR
FREQ SUPPLY
CURR
*
Use a separate
terminal for this
connection
NMEA NMEA
Figure 3-8 RI35 Mk2 - J45S Wiring diagram
Note ! Autopilot supply and Indicator supply must have common GND.
Connection to J101A/J200S Junction Units
J101A/J200S JUNCTION UNIT
RF100
RUDDER FEEDBACK UNIT
RI35 Mk2
RUDDER ANGLE
INDICATOR
SUPPLY VOLTAGE 12-24V DC
*
12 11 10
GND
RUDDER FB I/P
+OUT
BLUE
GREEN
RED
11
FREQ SUPPLYCURR
GREEN
* Non polarized (colour independant)
Use a separate terminal
for this connection
NMEA
RI35 Mk2
RUDDER ANGLE
INDICATOR
*
FREQ SUPPLYCURRNMEA
11
Move this connection to
the next instrument if two
are installed
Figure 3-9 RI35 Mk2 - J101A/J200S Wiring diagram
If more than two indicators are needed, use the NMEA port as per
Figure 3-10.