EasyManuals Logo

Sinee A90 Series User Manual

Sinee A90 Series
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
User Manual of A90 Series Inverter
102
on the
motor type
F14.09
Stator resistance of
asynchronous motor
1-60,000 (rated power of motor: ≤
75 kW)
0.1-6,000.0 (rated power of
motor: > 75kW)
mΩ
Depending
on the
motor type
F14.10
Rotor resistance of
asynchronous motor
1-60,000 (rated power of motor: ≤
75 kW)
0.1-6,000.0 (rated power of
motor: > 75kW)
mΩ
Depending
on the
motor type
F14.11
Leakage inductance
of asynchronous
motor
0.01 to 600.00 (rated power of
motor: ≤ 75 kW)
0.001 to 60.000 (rated power of
motor: > 75 kW)
mH
Depending
on the
motor type
F14.12
Mutual inductance of
asynchronous motor
0.1 to 6,000.0 (rated power of
motor: ≤ 75 kW)
0.01 to 600.00 (rated power of
motor: > 75 kW)
mH
Depending
on the
motor type
F14.13
No-load excitation
current of
asynchronous motor
0.01 to 600.00 (rated power of
motor: ≤ 75 kW)
0.1 to 6,000.0 (rated power of
motor: > 75 kW)
A
Depending
on the
motor type
F14.14
Flux weakening
coefficient 1 of
asynchronous motor
10.00 - 100.00
%
87.00
F14.15
Flux weakening
coefficient 2 of
asynchronous motor
10.00 - 100.00
%
80.00
F14.16
Flux weakening
coefficient 3 of
asynchronous motor
10.00 - 100.00
%
75.00
F14.17
Flux weakening
coefficient 4 of
asynchronous motor
10.00 - 100.00
%
72.00
F14.18
Flux weakening
coefficient 5 of
asynchronous motor
10.00 - 100.00
%
70.00
F14.19
-
F14.33
Reserved
F14.34
Motor parameter
0: No operation
0

Table of Contents