User Manual of A90 Series Inverter
107
F15.34
Fan control
0: running after power-on
1: running at startup
2: intelligent operation, subject to
temperature control
2
F15.35
Overmodulation
intensity
1.00 - 1.10
1.05
F15.39
Terminal jog priority
0: Invalid
1: valid
0
F15.40
Deceleration time for
quick stop
0.00 - 650.00 (F15.13=0)
0.0 - 6500.0 (F15.13=1)
0 - 65000 (F15.13=2)
s
1.00
F15.68
Energy price
0.00 - 100.0
1.00
F15.69
Power-frequency load
factor
30.0-200.0
%
90
F16
Customization function group
F16.00
Industry application
0: general model
1: air compressor application
2: extruder application
3: water pump application
4: fan application
0
F16.01
Set length
1 - 65535 (F16.13=0)
0.1 - 6553.5 (F16.13=1)
0.01 - 655.35 (F16.13=2)
0.001 - 65.535 (F16.13=3)
m
1,000
F16.02
Pulses per meter
0.1 - 6553.5
100.0
F16.03
Set count value
F16.04 - 65535
1,000
F16.04
Specified count value
1 - F16.03
1,000
F16.05
Set time of regular
running
0.0-6500.0; 0.0: invalid
min
0.0
F16.06
Agent password
0 - 65535
0
F16.07
Setting of cumulative
power-on arrival time
0-65535; 0: disable the protection
when the power-on time is up
h
0
F16.10
Setting of cumulative
running arrival time
0-65535; 0: disable the protection
when the running time is up
h
0
F16.09
Factory password
0 - 65535
XXXX
X
F16.10
Analog output
percentage
corresponding to the
count value 0
0.00-100.00
%
0.00
F16.11
Analog output
0.00-100.00
%
100.00