Page #112 background image
User Manual of A90 Series Inverter
112
protection
E02:
instantaneous overcurrent
E03:
instantaneous overvoltage
E04:
steady-state overcurrent
E05:
steady-state overvoltage
E06:
Steady-state undervoltage
E07:
input phase loss
E08:
output phase loss
E09:
inverter overload
E10:
inverter overheat protection
E11:
Parameter setting conflict
E13:
motor overload
E14:
external fault
E15:
inverter memory failure
E16:
communication abnormality
E17:
Temperature sensor
abnormality
E18:
disengaged soft start relay
E19:
current detection circuit
abnormality
E20:
stall failure
E21:
PID feedback disconnection
E22:
retention
E24:
parameter identification
abnormality
E25:
retention
E26:
off-load protection
E27:
up to the cumulative
power-on time
E28:
up to the cumulative running
time
F19.01
Output frequency in
failure
0.00 to upper frequency limit
Hz
0.00
×
F19.02
Output current in
failure
0.00 to 650.00 (rated power of
motor: ≤ 75 kW)
0.0 to 6500.0 (rated power of
motor: > 75 kW)
A
0.00
×
F19.03
Bus voltage in failure
0 - 1200
V
0
×
F19.04
Running status in
failure
0: not running
1: forward acceleration
2: reverse acceleration
3: forward deceleration
4: reverse deceleration
0
×