User Manual of A90 Series Inverter
172
the VF separation voltage)”, and the 7006H data range is 0.00% to 100.00%, as
detailed in Table 0-2.
Rise time of VF
separation voltage
The rise time of VF separation voltage refers to the time for the output voltage to
increase from 0 to the rated voltage of the motor.
Time t
Output voltage
0
Rated voltage
of motor
Set rise time
VF separation
voltage
Actual rise time
Fig. 7-20 Rise Time Description of VF Separation Voltage
Compensation gain of
V/F stator voltage drop
It is used to compensate for the voltage drop caused by the stator resistor and wire, and
improve the low-frequency load capacity.
V/F slip compensation
gain
As the load increases, the rotor speed of the motor will decrease. To make the rotor
speed of the motor close to the synchronous speed under rated load, slip compensation can
be enabled. When the motor speed is less than the target value, the set value of F05.11 can
be increased.
★
: In the case of F05.11=0, slip compensation is invalid. This parameter is valid only for
the asynchronous motor.