220
Function
code
Function
code name
Parameter description
Unit
Default
setting
Attribute
F12.14
Restoration
of default
setting
0: No operation
1: restoration of factory defaults
(excluding the motor parameters,
inverter parameters, manufacturer
parameters, running and power-on
time record)
0
You can set this parameter to 1 to restore the default settings of all parameters, except
the motor parameters (F01 group), inverter parameters, manufacturer parameters, power-on
time (F12.15/16) and operating time (F12.17, 18).
This operation is irreversible. Please set it carefully.
Function
code
Function code
name
Parameter description
Unit
Default
setting
Attribute
F12.15
Cumulative
power-on time h
0 - 65535
h
0
×
F12.16
Cumulative
power-on time min
0 - 59
min
0
×
F12.15 and F12.16 are used together to check the cumulative power-on time of the
inverter from delivery to the current moment (you only need to power on the inverter). The
cumulative power-on time is accurate to one minute and nearly 65,536 hours (about 7.5
years) at most.
If F12.15=50 and F12.16=33, it means that the current inverter has been powered on
for 2 days, 2 hours and 33 minutes.
This parameter can be viewed only and cannot be changed or cleared.
Function
code
Function code
name
Parameter description
Unit
Default
setting
Attribute
F12.17
Cumulative
running time
0 - 65535
h
0
×
F12.18
Cumulative
running time (min)
0 - 59
min
0
×
F12.17 and F12.18 are used together to check the cumulative operating time of the
inverter from delivery to the current moment (the inverter should be in the running status).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sinee A90 Series and is the answer not in the manual?

Sinee A90 Series Specifications

General IconGeneral
CoolingForced air cooling
Rated Power0.4kW to 500kW
Output Voltage0 to input voltage
Output Frequency0 to 400Hz
Overload Capacity150% for 60 seconds, 180% for 10 seconds
Braking UnitBuilt-in
CommunicationModbus
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit
Output Voltage (AC)0 to input voltage
Output WaveformSine wave
Output Frequency (AC)0 to 400Hz
Operating Temperature-10°C to +40°C (Derating above 40°C)
Storage Temperature-20°C to 65°C
DimensionsVaries with model
WeightVaries with model