User Manual of A90 Series Inverter
70
motor
speed)
F01.23
Initial electrical angle
of synchronous motor
0.0-359.9 (valid for synchronous
motor)
0.0
F01.24
~F01.3
3
Reserved
F01.34
Motor parameter
self-learning
0: No operation
1: static self-learning of
asynchronous motor
2: rotation self-learning of
asynchronous motor
11: static self-learning of
synchronous motor
2: rotary self-learning of
synchronous motor
0
F02
Input terminal function group
F02.00
Options of X1 digital
input function
0: no function
1: terminal running (RUN)
2: running direction (F/R)
3: stop control in three-line
operation
4: forward jog (FJOG)
5: reverse jog (RJOG)
6: terminal UP
7: terminal DOWN
8: clear UP/DOWN offset
9: free stop
10: reset fault
11: multi-segment speed terminal
1
12: multi-segment speed terminal
2
13: multi-segment speed terminal
3
14: multi-segment speed terminal
4
15: multi-segment PID terminal 1
16: multi-segment PID terminal 2
17: multi-segment torque terminal
1
18: multi-segment torque terminal
2
19: acceleration and deceleration
1
F02.01
Options of X2 digital
input function
2
F02.02
Options of X3 digital
input function
11
F02.03
Options of X4 digital
input function
12
F02.04
Options of X5 digital
input function
13
F02.07
Options of AI1 digital
input function
0
F02.08
Options of AI2 digital
input function
0