EasyManua.ls Logo

Sinee EM303A-030G/037P-3C User Manual

Sinee EM303A-030G/037P-3C
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
EM303A General Purpose Inverter
1
Preface
Thank you for purchasing EM303A series inverter.
Document No.: 31010005
Issue Date: 06/06/2013
EM303A is a general purpose inverter (Speed Sensorless Vector Control). It helps an
induction motor to achieve not only the speed regulation standard of a DC motor, but also
the control ability of a torque motor, and the motion control system is optimized with
quick response, precise control and system stability.
The updates of EM303A:
1. Support Modbus RTU standard communication protocol.
2. Support RS485 master-slave communication control mode, numeric synchronized
control achieved.
3. Numeric input terminals support F/R logic control, delay input control, and etc.
4. Numeric output terminals support PWL/pulse output, F/R logic output and delay output,
and etc.
5. Analog input signals VS/IS/VF/IF can be programmed as numeric inputs, numeric
terminals expansion control achieved.
6. With filtering, analog input signals VP/VS/IS/VF/IF can actively avoid analog signals
interference and drift.
7. User can easily define the display of function code menus.
8. Run, stop and parameters setting status can program the displayed parameters
independently.
It is the duty of any user to perform the appropriate, correct installation or configuration
of the optional parameters of the devices. Neither SINEE nor its distributors shall be
responsible or liable for misuse of the information contained herein or mismatching the
inverter with the motor.
In the interests of commitment to a policy of continuous development and improvement,
SINEE reserves the right to update the specification of the product or its performance, or
the content herein without notice.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sinee EM303A-030G/037P-3C and is the answer not in the manual?

Sinee EM303A-030G/037P-3C Specifications

General IconGeneral
Rated Power300W
Rated Input Voltage24VDC
Output Voltage230V AC
Output Frequency50Hz
ProtectionOverload, Short Circuit, Over Voltage, Over Temperature
CoolingFan
Operating Temperature-10°C to +50°C

Summary

Safety Information

Safety Precautions

General safety guidelines and warnings before operating the inverter.

Trial Operation

Maintenance and Inspection

2. INSTALLATION

2.1 Verifying Product

Steps to check and verify the EM303A inverter upon delivery.

3. WIRING

3.1 Connections to Peripherals

Illustrates how to connect external devices and peripherals to the inverter.

3.2 Wiring Main Circuit Terminals

Details on connecting the main power and motor circuit terminals.

3.3 Wiring Control Circuit Terminals

Explains the connections for control signals, inputs, and outputs.

4. KEYPAD OPERATION

5. TRIAL OPERATION

5.1 Trial Operation Procedures

Step-by-step guide for performing initial trial operations of the inverter.

5.2 Trial Operation Precautions

Important safety and operational advice for trial runs.

6. PARAMETER TABLES

6.2.2 Group F1: Motor Parameters

Parameters for configuring motor characteristics and settings.

6.2.8 Group E0: Fault Parameters

Parameters related to fault codes, descriptions, and troubleshooting.

7. PARAMETER DESCRIPTION

7.2 Group F1: Motor Parameters

Parameters for configuring motor characteristics and settings.

8 AUTOTUNING MOTOR PARAMETERS

8.1 Autotuning Motor Parameters

Explains the process and requirements for autotuning motor parameters.

8.3 Autotuning Procedure

Step-by-step instructions for performing motor autotuning.

9 TROUBLESHOOTING

9.1 Faults

Lists trip codes, causes, and corrective actions for inverter faults.

10 MAINTENANCE AND INSPECTION

12 COMMUNICATION PROTOCOL OF EM303A

Related product manuals