User Manual of EM730/EM730E Series Inverter
265
Deceleration time
for quick stop
0.00 - 650.00 (F15.13=0)
0.0 - 6500.0 (F15.13=1)
0 - 65000 (F15.13=2)
Set the acceleration and deceleration time during rapid stop.
Overcurrent
detection level
0.1-300.0 (0.0: no detection;
100.0%: corresponding to the
rated current of motor)
Overcurrent
detection delay time
When the current exceeds the overcurrent detection level (F15.66) and the duration reaches
F15.67, the function “73: output overcurrent” of the output terminal will be valid.
Set the current electricity price in the market and calculate the electricity savings. The
electricity savings can be viewed by the function codes F18.69 and F18.70.
Power-frequency
load factor
Set the coefficient of the power frequency load.
7.17 F16 customized function parameter group
0: Universal model
1: Water supply application
2: Air compressor application
3: Winding application
4: fan application
5: Spindle application of
machine tool