17
| Instruction Manual and Parts List
3.20
Movable
and Fixed
Knives Position
Removing the fixed knife (Figure 27)
Remove the screw ‘1’ and rotating
hook positioner ‘2’.
Remove the screw ‘3’ and the fixed
knife ‘4’.
Lift the presser foot up by the presser
foot lift lever.
plate ’6’.
Removed the screw ‘5’ and the needle
Turn the hand wheel until the needle
bar is at its highest position.
Remove the screws ‘7’ and the mova-
ble knife ‘8’.
* Installation is performed by reversing the above order.
Use the socket spanner ‘9’ to loosen
the nut ‘10', then turn the screw ’11’
until desired pressure of fixed knife.
‘12’.
Figure 29
1
2
7
3
4
6
5
8
Adjustment
Tilt the machine head until it stops.
Figure 27
Figure 28
Removing the movable knife (Figure 28)
Adjusting pressure of fixed knife
(Figure 29)
plate ’6’.
Removed the screw ‘5’ and the needle
9
11
10
12