10
In program submenu, use esc key to get back to the programs menu.
Strike any key to clear the error messages which may be displayed on LCD
screen. Menu Structure can be found in section 4.H.
Create a program:
When executing the "create a program" function, the program submenu is
acceded, starting with the identification. The initial identification "Pxx NO NAME" is
given to the program and all parameters are established to zero; the program
number is allocated automatically.
Delete a program:
When executing the "delete a program" function, the programs menu is acceded
and the number of the first program in memory is blinking to point out the deletion
mode. Use select key to select a program and enter key to accede
and confirm deletion of the selection. Use esc key to unconfirm a deletion
and to leave the function. When leaving the function, the number of the actual
program on LCD screen cease to blink.
Program identification:
For a selected program, set the identification, using the numeric keyboard
characters chart; press numeric key until the desired character is selected (4 times
for the numeric value). Use enter key to validate the character and to
validate the characters string at the end (the new characters string is blinking). In a
middle of an acquisition, use esc key to come backward and erase one or
several characters.
For example, to use a ‘E’ caracters, press number 2 two times and une the enter
key to confirm.
b. Vacuum level setting
For a selected program set the vacuum level, starting with the values; the decimal
point is automatically inserted following the second digit entry and the validation is