“D9 ACCESS CODE” Enable or disable the access code to modify the programs
“D10 CODE CHANGE” Modify the program access code
"D11 PUB” Enable or disable the screen saver message
“D12 SELECT PUB” Factory use
“D13 VACUUM CALIB” Automated calibration sequence
"SYSTEM MONITOR" (no access code required)
"SOFTWARE: R x.xx" Show the software version
"WORK HRS: xxxxx" Show the number of operating hours
"CYCLES: xxxxxxx" Show the total number of cycles
S: XXX.X T: XXX.X Show the set point and the current temperature for the heating
option
5. Daily cleaning
For hygienic cleanliness, it is imperative to clean chamber and spacers daily. Also
clean the lid rubber to assure tight seat of the lid. The 350/350D is made to be
clean by hand with a damp cloth, no water can be apply directly on the machine.
Cleaning instructions for gas injection nozzles (option): Periodically, on a
regular basis, the gas injection nozzles must be removed with the connection tube
and soaked in a food grade soap and water solution, then dried and re-installed.