e. Sealing time setting
For a selected program set the sealing, starting with the seconds; the decimal point
is automatically inserted following the first digit entry and the validation is
automatically performed following the third digit entry (the new sealing time is
blinking. In a middle of an acquisition, use enter key to validate the sealing
time and use esc key to come backward and start over with a new
acquisition (the old sealing time is blinking).
f. Packaging cycle
Chose a program (see basic section) and place the bags on the sealing bar, close
the cover to initiate a vacuum cycle. During cycle execution the operation status is
sequentially displayed on LCD screen, except for the parameters established to
zero, which are not displayed:
Vacuum status % during vacuum sequence
Vacuum plus time (seconds)
Gas status % during gas flush sequence
Sealing time status during sealing sequence (seconds)
ATM message during venting sequence
During cycle execution, use key "1" to abort the vacuum sequence and execute the
following sequence, which is gas flush or sealing, use enter key to accede
and modify the program; the parameters become valid only for the following
vacuum cycles.
g. System monitor and diagnostic menu
To access the diagnostics menu, power up the vacuum packaging machine
while keeping pushed in esc key . Use select key to select
the system monitor function and enter key to access and visualize the
monitored parameters. A password is required for some menus, contact your
service center for support. Use select key to change over from the
software revision, the amount of working hours done and the amount of complete
cycles performed since first initialization. See menus structure next.