The gas pipe must be suitably protected where it passes through fireplace openings. Any sleeving should
be sealed to the pipe at its ends.
The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt
during installation.
Thread the cable tensioners onto the cable as shown, with the nuts screwed down close to the tensioner
head.
Slide the screwed nipple through the box and pull cable taut and tighten pinch screw on to the cable.
Adjust tensioner using a suitable spanner to pull the cable tight into position, to allow an even seal around
the edge of the fire, visually inspect the seal and reseat if necessary.
Note: Fibre Rawlplugs might be preferred rather than plastic Rawlplugs as the heat from the
fire might affect their efficiency.
Pinch screw
Tension nut
Surplus tension cable MUST NOT be cut off as this will
prevent proper installation after servicing simply coil up
the surplus cable as shown and tuck the coils out of the
way.
Fixing by screw:
Mark and drill the fire frame or base, and relevant
points in the opening or on the wall. Raw plugs will be
required.