~11~
[llJ
Puller Height Adjustment (Model
927-S/M·PL)
Adjust the height
of
puller 0 so
that
it is
0.1
to
0.2
mm high from
the
top
of
the needle plate.
(AdjU8ting
Method)
Loosen
set
screw
e.
and move puller support 8
up
or
down until
puller
8 is
0.1
to 0.2
mm
above the top
of
the needle plate.
~
Puller Device Timing Adjustment (Model FA007-264/DP)
1.
With
3mm wrench
to
loosen
the
screw
8 &
2.
The
timing
of
the
feed will be
starting
when
the
needle ia
away
from
the
needle
plate
about
5
or
6mm,
and
etoping
at
lOmm.
3.
After
adjusting
the
timing,
retighten
the
screw
0 .
0