Installation instructions
Compliant with Directive 2006/42/EC
SKF 40PGA Pump
Pneumatic central lubrication system pump
EN
Version 02

Table of Contents

Other manuals for SKF 40PGAP-170-24-PS

Questions and Answers

  • S
    Stephen MarshallAug 11, 2025
    Why does my SKF Water Pump start but the pressure doesn't increase?
    • H
      Hannah GardnerAug 11, 2025
      If your SKF Water Pump starts but the pressure isn't increasing, several factors could be at play: * Insufficient air pressure: Ensure the air pressure is approximately 6–8 bar. * Air in the pump’s piping: Bleed the system to remove any trapped air. * Empty lubricant reservoir: Add lubricant to the reservoir. * Air in the lubricant reservoir or lubricant: Empty the reservoir and refill it with new grease. * Lubricant viscosity too high: Check the lubricant viscosity and replace it if necessary, using NLGI-000...NLGI-1.
  • S
    suzanne56Aug 20, 2025
    What to do if my SKF Water Pump does not start?
    • S
      shawnjohnsonAug 20, 2025
      If your SKF Water Pump isn't starting, here are a few things to check: * Pressurized air supply: Make sure the pressurized air inlet is open. * Air pressure: Inspect the pressure air supply hoses for any leaks. * Supply voltage: Confirm that the supply voltage has been switched on in the control center.
  • A
    agonzalezAug 31, 2025
    How to fix a heavy pumping manual filling device on SKF Water Pump?
    • B
      Brittany KelleyAug 31, 2025
      If you are having trouble filling the SKF Water Pump with a manual filling device because the pumping feels too heavy, you should check and clean the filling inlet filter.