User manual
Copyright 2016 by SKF Group
All rights reserved.
SKF Sverige AB
Aurorum 30, 977 75 Luleå, Sweden
Telephone: +46 (0) 31 337 10 00
SKF Multilog On-Line
System IMx-S
User Manual Part No. 32087700-EN
Revision S November 2019
WARNING! Read this manual before using the product. Failure to follow the
instructions and safety precautions in this manual can result in serious injury, damage to
the product, or incorrect readings. Keep this manual in a safe location for future
reference.

Questions and Answers

  • V
    Virginia IngramAug 12, 2025
    What to do if an SKF Multilog IMx-S Control Systems sensor repeatedly generates a false alarm?
    • S
      Sarah LopezAug 12, 2025
      If a sensor is generating false alarms or varying abnormally, first perform a sensor/cable test. Also, check the sensor mounting. If the issue persists, consider contacting SKF Condition Monitoring Center Luleå.
  • S
    Stephen ThomasAug 15, 2025
    How to troubleshoot SKF Multilog IMx-S when sensor signal disappears?
    • D
      Daniel FloresAug 16, 2025
      If the sensor signal disappears or changes abnormally for single channels, perform a sensor/cable test.
  • M
    marisasullivanAug 19, 2025
    What to do if SKF Multilog IMx-S analogue input gives no signal?
    • C
      Carrie RyanAug 20, 2025
      If the analogue input gives a faulty or no signal, perform a sensor/cable test.
  • J
    jmathisAug 23, 2025
    How to fix speed signal that is unobtainable/faulty on SKF Multilog IMx-S?
    • A
      Amber CunninghamAug 23, 2025
      If the speed signal is unobtainable or faulty for a particular machine, test the speed input.
  • O
    Omar Johnson PhDAug 27, 2025
    What to do if SKF Control Systems load input gives no signal?
    • J
      Jamie HallAug 27, 2025
      Since the load input acts as an analogue input, start by performing a cabling/input test. If the problem continues, contact SKF Condition Monitoring Center Luleå.
  • W
    wellsannaAug 31, 2025
    What to do if SKF Control Systems monitor ceases to work with IMx-S unit?
    • D
      Douglas HernandezAug 31, 2025
      If the monitor stops working with a specific IMx-S unit, check the voltage of the IMx-S unit and examine the Ethernet built-in LED indicator behavior.
  • R
    Robert JacksonSep 3, 2025
    Why SKF Multilog IMx-S sensor is not receiving power?
    • A
      Antonio GomezSep 4, 2025
      If the sensor is not receiving power, verify the DIP switching. If DIP switching is not the cause, contact SKF Condition Monitoring Center Luleå.
  • K
    Kristina Mclaughlin MDSep 7, 2025
    What to do if the fault is in the analogue input part of the SKF Control Systems IMx-S unit?
    • J
      jonesnatashaSep 7, 2025
      If the fault is in the analogue input part of the IMx-S unit, contact SKF Condition Monitoring Center Luleå.

Summary

Introduction to SKF Multilog On-Line System IMx-S

Important Messages for IMx-S Users

Crucial safety and operational information for a safe and reliable system.

SKF Multilog On-Line System Overview

Overview of the IMx-S within the SKF Multilog On-line System product range.

SKF IMx-S Unit Description

Detailed description and specifications of the IMx-S unit, including models.

IMx-S System LED Indicators

Explanation of the system's status indicators, including SYS and PWR LEDs.

Installation of SKF IMx-S System

Safety Considerations During Installation

Critical safety precautions and site requirements for installing the IMx-S unit.

Installation Scenario and Planning

Guidance on assessing and planning the installation location and layout for the system.

SKF IMx-S Supply Cable Requirements

Recommendations for power supply cables, including type and connection requirements.

Mains Power Connection Procedures

Detailed instructions for connecting the power cable to the mains power grid safely.

Sensor Cable Installation Guidelines

Recommended sensor cable types and routing considerations to maintain signal integrity.

Ethernet Cable Specifications

Specifications for Ethernet cables, including types for different lengths.

Ethernet Connection Setup

Information on connecting the IMx-S unit via Ethernet ports and their functionality.

Cable Gland and Entry Requirements

Guidelines for using cable glands and blind plugs for proper enclosure sealing and fire protection.

SKF IMx-S Unit Configuration

Analogue Input Configuration

Details on terminal connections and DIP switch settings for analogue sensors.

Digital Input Configuration

Information on terminal lists and DIP switch settings for digital input configuration.

RS485 Communication Setup

Configuration details for RS485 communication, including termination resistors.

Relay Driver Output Configuration

Overview of the IMx-S relay driver outputs and their terminal connections.

Dig1 Buffered Output Configuration

Description of the Dig1 buffered output and its connection to a tachometer input.

Network Configuration and Unit ID Setup

Steps and considerations for configuring network settings and unit IDs.

Setting IMx-S Unit Time

Methods for setting and synchronizing the IMx-S unit's time.

SKF IMx-S Hardware Maintenance

Hardware Maintenance Overview

Information on the maintenance requirements for the IMx-S hardware.

Troubleshooting SKF IMx-S System

Troubleshooting Sensor Circuits

Diagnosing and resolving issues related to sensor circuits and connections.

Checking Vibration Channels

Step-by-step guide to troubleshoot non-responsive 2-wire accelerometer channels.

Troubleshooting Eddy Current Probe Inputs

Troubleshooting steps for eddy current probe inputs, including voltage and signal checks.

Troubleshooting 4-20 mA Channels

Diagnosing issues with 4-20 mA channels, checking DIP settings and wiring.

Troubleshooting Analogue Input Channels

Troubleshooting analogue input channels, verifying connections and voltage measurements.

Troubleshooting Digital Input Channels

Steps to troubleshoot digital input channels, including sensor power and signal checks.

Troubleshooting Relay Driver Outputs

Diagnosing issues with relay driver outputs, checking voltage and connections.

Troubleshooting Connections to Monitor

Troubleshooting loss of connection to the monitoring system.

Checking Modbus RTU and RS485 Communication

Diagnosing communication problems with Modbus RTU and RS485 interfaces.

Technical Data for SKF IMx-S

Environmental Specifications

Specifications related to the operating environment, size, and weight.

Power Supply Specifications

Details on the power supply requirements and consumption of the IMx-S unit.

Analogue Input Technical Data

Technical specifications for analogue differential inputs.

Digital Input Technical Data

Technical specifications for digital opto-isolated inputs.

Output Specifications

Specifications for relay driver and system relay outputs.

Analogue Measurement Capabilities

Details on the analogue measurement capabilities, including AD conversion.

Digital Measurement Specifications

Technical specifications for digital measurement, including frequency range.

Signal Processing Features

Description of signal processing techniques used by the IMx-S.

Interface Specifications

Information on Ethernet and RS232 service interfaces.

Data Processing Details

Details on the RAM used for data processing.

Miscellaneous Technical Data

Miscellaneous technical details like calibration and certifications.

Quality Control Information

Information about SKF's quality certifications.

SKF IMx-S Drawings and Diagrams

IMx-S 16 Standard Cabinet Drawing

Dimensional drawing of the IMx-S 16 standard cabinet.

IMx-S 16 Stainless Steel Cabinet Drawing

Dimensional drawing of the IMx-S 16 stainless steel cabinet.

IMx-S 32 Cabinet Drawings

Dimensional drawings for IMx-S 32 standard and stainless steel cabinets.

SKF IMx-S Terminal List

A comprehensive list of all terminals on the IMx-S unit.

Electrical Waste Disposal Guidelines

Proper Recycling of Electrical Waste

Guidelines for the proper recycling and disposal of electrical waste.

SKF IMx-S Limited Warranty Information

SKF Limited Warranty Terms and Conditions

Details of the warranty terms, conditions, and periods for SKF products.

SKF Multilog IMx-S Series Specifications

General IconGeneral
BrandSKF
ModelMultilog IMx-S Series
CategoryControl Systems
LanguageEnglish