EasyManuals Logo

SKF SYSTEM 24 LAGD 60 User Manual

SKF SYSTEM 24 LAGD 60
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
10 SKF SYSTEM 24 - LAGD 60 / LAGD 125
5. Problem solving
Problem Possible causes Action
Lubricator does
not dispense or
dispenses too slowly
Incorrect adjustment Adjust the dispense rate
Lubricator is not activated Activate the lubricator time
set dial
Lubrication channels are
blocked
Clear the blockage by
forcing grease with a
grease gun through the
lubrication channels
The resistance is too high Make sure that:
- excessive grease can
escape
- supply lines are not
longer than 300 mm
- supply lines have a inner
diameter of 6 mm
- Lubrication point is
suitable for gas driven
lubricators
Lubricant dispenses too
quickly
Incorrect adjustment Adjust the dispense rate
Short term temperature
peak
No corrective action
needed
Air between the piston
and the lubricant
Installed longer period than
the selected time
Replace the unit
The ambient temperature
is more than the acceptable
limit
Replace the unit and
protect the unit against
high ambient temperatures
Lubricator neck breaks Too high vibration or
impact
Support the unit with
the clamp LAPC 50 or
protection plate LAPP 4
If the lubricator still fails to operate, damaged SKF SYSTEM 24 LAGD shall be replaced
and moved to non-hazardous zone. Contact your local SKF SYSTEM 24 supplier.
User repair is prohibited.
Material safety data sheets for the LAGD 60/125 and for the lubricants used can be found
at www.mapro.skf.com.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF SYSTEM 24 LAGD 60 and is the answer not in the manual?