EasyManua.ls Logo

Skyjack SJ 4620 - Table 2.5 Maximum Platform Capacities (Evenly Distributed)

Skyjack SJ 4620
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TM
Page 62 December 2007
SJIII Compacts & Conventionals
Tables Section 2 - Operation
Table 2.5 Maximum Platform Capacities (Evenly Distributed)
227 kg 2 Persons 113 kg 1 Person No Wind
227 kg 1 Persons 113 kg 1 Person 9.4 m/s
227 kg 2 Persons 113 kg 1 Person No Wind
227 kg 1 Persons 113 kg 1 Person 9.4 m/s
3220
408 kg 2 Persons 113 kg 1 Person 408 kg 2 Persons 113 kg 1 Person No Wind 1.5 x 3.5
3226
227 kg 2 Persons 113 kg 1 Person No Wind 1.5 x 3.5
4620
590 kg 3 Persons 136 kg 1 Person 590 kg 3 Persons 136 kg 1 Person 12.5 m/s 1.5 x 3.5
4626
454 kg 2 Persons 136 kg 1 Person 12.5 m/s 1.5 x 3.5
317 kg 2 Persons 113 kg 1 Person No Wind
317 kg 1 Person 113 kg 1 Person 9.4 m/s
132AB
3215
3219
N/A
N/A
4632
N/A
N/A
MODEL
Manual Extension Platform Powered Extension Platform
Total Capacity Extension Capacity Total Capacity Extension Capacity
Tilt
Cutout
Setting
Maximum
Wind
Speed
N/A
1.5 x 3.5
1.5 x 3.5
1.5 x 3.5
NOTE: Overall Capacity - Occupants and materials not to exceed rated load.
m/s km/h ft/s mph
3
3.4 – 5.4 12.5 – 19.4 11.5 – 17.75 8 – 12 Papers and thin branches move, flags wave
4
5.4 – 8.0 19.4 – 28.8 17.75 – 26.25 13 – 17
Dust is raised, paper whirls up, and small
branches sway.
5
8.0 – 10.8 28.8 – 38.9 26.25 – 35.5 18 – 24.25
Shrubs with leaves start swaying. Wave crests are
apparent in ponds or swamps.
6
10.8 – 13.9 38.9 – 50.0 35.5 – 45.5 24.5 – 31
Tree branches move. Power lines whistle. It is
difficult to open an umbrella.
7
13.9 – 17.2 50.0 – 61.9 45.5 – 56.5 31 – 38.5
Whole trees sway. It is difficult to walk against the
wind.
138AA-CE
Wind Speed
Ground Conditions
BEAUFORT
SCALE
WARNING
This aerial platform is equipped with a load sensing system. Do not exceed the rated capacity of
the aerial platform. Failure to avoid this will prevent operation of all normal controls/functions of
the aerial platform. To resume normal operation remove the additional loads.