Page 36 December 2007
SJ46AJ SJ51AJ SJ63AJ
It is the responsibility of the operator to read, completely understand and follow all
instructions and warnings contained in this operating manual and on the MEWP.
FAMILIARIZATION
• Test Platform Emergency Stop
1. Start engine by selecting “ ” start
position from engine start/on/off switch.
Result: Engine should start.
2. Push in “ ” emergency stop button.
Result: Engine should shut down and
MEWP functions should not operate.
• Test Footswitch
1. Pull out “ ” emergency stop button.
2. Ensure engine start/on/off switch is in
“ ” on position.
3. Do not start engine.
4. Select generator on/off switch to off
position (if equipped).
5. Depress and hold footswitch and attempt
to start engine by selecting “ ” start
position from engine start/on/off switch.
Result: Engine should not start.
6. Without depressing footswitch, try to start
engine.
Result: Engine should start.
7. W ith engine running and witho ut
depressing footswitch, test each boom
and platform function.
Result: MEWP functions should not
operate.
NOTE
A 15-second anti-tiedown feature
deactivates footswitch when operator
depresses it for 15 seconds without
activating any function.
• Test Engine Start/On/Off Switch
1. Ensure engine is running.
2. Select “ ” off position from engine start/
on/off switch.
Result: Engine should shut down and
platform control console is disabled.
3. Select “ ” on position from engine start/
on/off switch.
Result: Pl
Platform Control
Console
Footswitch
Emergency Stop
Drive/Steer
Controller
Tie-off PointTie-off Point
Function Tests Section 2 - Familiarization