SETTING THE TEMPERATURE SWING (TEMPERATURE DIFFERENTIAL)
1. To change the temperature “SWING” setting (1-3), press the TIMER/TIME and DOWN buttons simultaneously (Fig. 18)
to display the current “SWING” setting in the SET TEMP frame. The letter “S” will display in the ROOM TEMP frame
on the LCD screen.
2. Press the UP or DOWN button to change the temperature differential or “SWING” (1-3). See above for 1-3 “SWING”
temperature valves.
3. To store the “swing number press the SET button or allow 15 seconds to lapse, and the new “swing number’ will be
automatically programmed.
MANUAL CHECK OF “ SWING” OR TEMPERATURE DIFFERENTIAL
The operation of the factory set “THERMO SWING” can be
checked by adjusting the SET temperature 2° F above or below
the room temperature. This will cause the system to turn ON
or OFF. Normally the system will only respond to temperature
changes every two minutes. Manually changing the SET tem-
perature will activate the system in less than 10 seconds. IF the
“SWING” is changed, then a new room temperature differential
will respond. Factory setting of “SWING”
temperature is 2° F.
ROOM
SET
Fig. 20 Low Battery Sign
ROOM
SET
Fig. 18. Setting Swing Temperature
MODE
TIMER
TIME
SET
SETTING THE COUNTDOWN TIMER
This remote control system can operate with a built-in countdown timer when the transmitter is in the ON or THERMO
modes only (THERMO or ON must be displayed on the screen).
1. Press and release the TIMER/TIME button on the transmitter.
The word TIMER will appear and 0:15 minutes will begin
blinking on the screen (Fig. 19).
2. Press the UP or DOWN button on the transmitter to begin
advancing through each of the countdown time options.
Available countdown times are 15 minutes, 30 minutes,
45 minutes, 1 hour, 1 hour 30 minutes, 2 hours,
2 hours 30 minutes, and each additional half-hour up to nine
(9) maximum hours.
3. To set the TIMER press the SET button on the transmitter if the
system is ON. It will remain ON until the time has expired. If
the system is in the THERMO mode, it will cycle on and off,
as the room temperature requires until the “time” has expired.
OPERATIONAL NOTE: When the timer is used in the THERMO mode, the THERMO operation will resume when the
“time” has expired.
ROOM
SET
Fig. 19 Setting Timer
MODE
TIMER
TIME
SET
LOW BATTERY INDICATOR
A low battery icon will be visible in the upper left corner of the LCD screen when
battery power has dropped signicantly (Fig. 20). At this time, approximately two weeks of
battery power remains until the transmitter may experience partial or complete loss of
functions.

Other manuals for Skytech 1001-A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skytech 1001-A Series and is the answer not in the manual?

Skytech 1001-A Series Specifications

General IconGeneral
TypeRemote Control
Model1001-A Series
BrandSkytech
CategoryFireplace Remote Control
CompatibilitySkytech Fireplace Systems
Power SourceBattery

Related product manuals