Installation Manual SMC9-11TLRP-IA-en-51 27
SMA Solar Technology AG 5 Mounting
Observe recommended clearances:
Observe the recommended clearances to the walls as well as to other inverters or objects.
This ensures adequate heat dissipation and sufficient space to remove the ESS.
If multiple inverters are mounted in areas with high ambient temperatures, increase the
clearances between the inverters and ensure an adequate fresh-air supply.
This prevents a reduction in inverter power as a result of high temperatures (details on
temperature derating can be found in the Technical Information "Temperature Derating" at
www.SMA-Solar.com).
Observe the permitted mounting position:
Mount the inverter in a permitted mounting position. The display should be mounted at eye level.
Mounting the inverter in a permissible position will ensure that no moisture can enter.
By mounting the device at eye level, display messages and LED signals can be read without
difficulty.
Figure 9: Recommended clearances
Figure 10: Permitted and prohibited mounting positions