Installation Manual SMC9-11TLRP-IA-en-51 89
SMA Solar Technology AG 12 Technical Data
According to IEC 60721-3-4, Installation Type C, Class 4K4H
According to IEC 60721-3-4, Transport Type E, Class 2K3
12.3 Protective Devices
DC reverse polarity protection Short-circuit diode
DC disconnect device Electronic Solar Switch
DC overvoltage protection Thermally monitored varistors
AC short-circuit current capability Current control
Grid monitoring SMA Grid Guard 2.1
Maximum permissible fuse protection 80 A
Earth-fault monitoring Insulation monitoring: Riso > 280 k Ω
All-pole sensitive residual-current monitoring unit Available
12.4 Approvals
Country standard,
as per 11/2012
SMC 9000TLRP-10 SMC 10000TLRP-10 SMC 11000TLRP-10
VDE 0126-1-1 ✓ ✓ ✓
VDE-AR-N 4105 ✓ ✓ ✓
UTE C15-712-1 ✓ ✓ ✓
C10/C11 ✓ ✓ ✓
PPDS ✓ ✓ ✓
RD 1663 ✓ ✓ ✓
RD 661 ✓ ✓ ✓
EN 50438
*
* EN 50438: Does not apply to all national variations of the standard.
✓✓✓
GBT19939-2005 ✓ ✓ ✓
CGC GF001-2009 ✓ ✓ ✓
12.5 Climatic Conditions
Extended temperature range − 25°C … +60°C
Extended humidity range 0% … 100%
Extended air pressure range 70.0 kPa … 106 kPa
Temperature range − 25°C … +70°C