5 Mounting
SMA Solar Technology AG
Operating manualSTP15-25TL-30-BE-en-1722
1382
2224
530
50
400
190
315
415
438
415
940
Figure 5: Recommended clearances(Dimensions in mm)
5.2 Mounting the Inverter
Additionally required mounting material (not included in the scope of delivery):
At least two screws suitable for the support surface (diameter: 10mm at maximum)
At least two washers that are suitable for the screws (diameter: 30mm at maximum)
If necessary, two screw anchors suitable for the support surface and the screws
For transporting the inverter with a crane: two eye bolts suitable for the weight of the inverter
(size: M10)
To secure the inverter from being lifted off: two screws suitable for the support surface, two
washers suitable for the screws and - depending on the support surface - two screw anchors
suitable for the support surface and the screws
CAUTION
Risk of injury when lifting the inverter, or if it is dropped
The inverter weighs 61kg. There is risk of injury if the inverter is lifted incorrectly or dropped
while being transported or when attaching it to or removing it from the wall mounting bracket.
Transport the inverter always as described below.