Loading...
SMA Solar Technology AG STP60 SunSpec Modbus Profile Assignment Tables
5.2 Gateway (Unit ID = 125)
In the following tables you will find the SunSpec Modbus registers provided by the gateway
(Inverter Manager) that you can access under unit ID = 125. You can access the gateway via the
IP address of the Inverter Manager:
5.2.1 Table C 001 (Common Model)
No.
(DEC)
Description/Number Code(s)
CNT
(WORD)
Type
Access
Header:
40001
SunSpec ID (SID): 0x53756e53 = SunSpec Modbus Map
2
uint32
RO
40003
Model ID (ID): 1 = SunSpec Common Model
1
uint16
RO
40004
Number of the following Modbus registers in accordance with
the PICS table (L): 66
1 uint16 RO
Fixed block:
40005
Manufacturer (Mn): "SMA"
16
string
RO
40021
Model (Md): "SMA Inverter Manager"
16
string
RO
40037
Options (Opt): "Inverter Manager name"
8
string
RO
40045
Version (Vr): Version number of the installed firmware.
8
string
RO
40053
Serial number (SN) of the device that uses the Modbus unit ID
stored in the following register.
16 string RO
40069
Modbus unit ID of the device (DA):
125: Inverter Manager
1 uint16 RO
40070
Padding register (Pad): NAN
1
pad
RO