13
The event notification function allows you to activate the sending
of e-mail messages about selected events occurring with the
device.
Example: If it is necessary to turn off the relay when the voltage
exceeds 260V and turn on the relay when the voltage returns to
250V, then two conditions must be enabled:
1) V > 260 Relay OFF
2) V < 250 Relay ON
Hysteresis is set only for the action - sending an e-mail. The
hysteresis is designed to prevent the sending of repeated e-mail
messages when the value of the selected data continues to meet
the specified condition.
Important! Set the hysteresis value high enough to avoid spam.
Example of hysteresis operation for condition: V> 260 e-mail
Hysteresis: 20
To activate the condition, you must select the data type, select
the comparison sign ">" or "<", enter the value for comparison,
select the required action.