33 | CHAPTER 5 – TROUBLESHOOTING YOUR SMART BOARD INTERACTIVE
WHITEBOARD
Troubleshooting using SMART Board
Diagnostics
If you touch the interactive whiteboard’s surface and nothing happens, or if there is no
digital ink or the ink appears in some locations and not in others, use SMART Board
Diagnostics to help identify and resolve these issues.
IMPORTANT
Do not change diagnostic settings unless asked to do so by SMART Technical
Support.
Checking the camera view
If nothing happens when you touch the interactive whiteboard’s surface, check to
make sure that nothing is obscuring one of the cameras’ views.
To check camera views 1. Press the SMART Board icon in the Windows notification area or
Mac Dock, and then press Control Panel.
The SMART control panel opens.
2. Select About Software and Product Support > Tools > Diagnostics.
The SMART Board Diagnostics window opens.
3. In the View menu, select SBX800 Bar.
The SBX800 group box appears in the SMART Board Diagnostics window.
4. Press the View button.
The camera view window appears.
5. Click Update to show what each of the four cameras sees. This may take a few
moments.
If one of the camera’s views remains black, the camera is obstructed or can’t
locate the reflective surface on the interactive whiteboard’s inner frame.
6. Check the camera lens and ensure that nothing is obscuring the view and that
nothing is affixed to the interactive surface.

Table of Contents

Other manuals for SMART Board X885

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMART Board X885 and is the answer not in the manual?

SMART Board X885 Specifications

General IconGeneral
BrandSMART
ModelBoard X885
CategoryInteractive whiteboard
LanguageEnglish

Related product manuals