Analogue Input/Output unit parameters (continued)
No.
Parameter
Definition
Item
Content
Default
setting
Parameter
setting range
8
Monitor lower
limit
Generates error
when the input or
output value falls
below the user
setting value.
Enable
Generates an error.
1
Channel
Disable
Does not generate an
error.
Scale setting
value lower
limit
Sets the scale
lower limit.
Generates error
when the input or
output value falls
below the lower
limit.
Enable
Generates an error.
Value: -32767 to 32766
Disable
Does not generate an
error.
Value: -32767 to 32766
Value: 0
9
Fault mode
2
Sets output when
communication
error is occurred.
Enable
Output will be user fault
value.
1
Channel
Disable
Output will be held last
state.
10
Idle mode
2 3
Sets the output
during
communication
idling.
Enable
Output will be user idle
value.
1
Channel
Disable
Output will be held last
state.
1: Set value shall be set per analogue input/output range within settable range in the next page table.
When the analogue input/output range is changed, check the set value, and change it to an appropriate value.
2: This function is valid only when “Hold/Clear priority” of the system parameter (page 51) is set to “Via software”.
3: Some PLC does not support an idle mode.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks EX600-ED Series and is the answer not in the manual?

SMC Networks EX600-ED Series Specifications

General IconGeneral
BrandSMC Networks
ModelEX600-ED Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals