-67-
EX※※-OMR1012
Channel parameter object (1) (Class: 79h to 7Fh)
Class Instance Attribute Access Name Type Value
79h
Open circuit detection
•SI
•Digital input (DX
C1)
•Digital output, I/O
BOOL
0: Disable
1: Enable
7Ah
ON/OFF count upper limit
detection
•SI
•Digital input, output, I/O
BOOL
0: Disable
1: Enable
7Bh
ON/OFF count upper limit value
•SI
•Digital input, output, I/O
UINT
1 to 65000
(Times diagnosis is detected=Set
value x1000)
7Ch
Analogue user setting value upper
limit detection
•Analogue input, output, I/O
BOOL
0: Disable
1: Enable
7Dh
Analogue user setting value of
upper limit
•Analogue input, output, I/O
UINT
2 bytes AD value
Refer to “Parameter Setting” for
details.
7Eh
Analogue user setting value lower
limit detection
•Analogue input, output, I/O
BOOL
0: Disable
1: Enable
7Fh
01h to
0Ah
1
64h to
83h
2
Get/Set
Analogue user setting value of
lower limit
•Analogue input, output, I/O
UINT
2 bytes AD value
Refer to “Parameter Setting” for
details.
1: The instance number 01h to 0Ah is allocated to the Unit No. from 0 to 9.
2: The attribute number from 64h to 83h is allocated to the channel No. from 0 to 31.

Other manuals for SMC Networks EX600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks EX600 Series and is the answer not in the manual?

SMC Networks EX600 Series Specifications

General IconGeneral
BrandSMC Networks
ModelEX600 Series
CategoryI/O Systems
LanguageEnglish

Related product manuals