EasyManua.ls Logo

SMC Networks ISE20B - Product Individual Parameters (Part 2); OUT1 Normal;Reversed Output Mode; OUT1 Set Value and Hysteresis; OUT1 Window Comparator Settings

Default Icon
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-70-
No.PS※※-OMV0006-D
Product individual parameters (continued)
Index
(dec)
Sub
index
Access
1
Parameter
Data
storage
2
Date
type
3
Initial value
(dec)
Remarks
0x03F3
(1011)
0 R/W
1ot
(Selection of
OUT1
normal/reversed
output mode)
Y U8
0x00
(0)
Setting of OUT1 output normal and
reserved output
0: 1_P (Normal output)
1: 1_n (Reserved output)
0x03F4
(1012)
0 R/W
P_1(n_1)
(Setting of
OUT1 output
set value)
Y U16
ISE20B: 0x0BB8
(3000)
ZSE20B: 0x0BB8
(3000)
ZSE20BF: 0x0FA0
(4000)
Setting of OUT1 output set value
Setting range
ISE20B: 0x0244 ~ 0x1450
(580 ~ 5200)
ZSE20B: 0x0258 ~ 0x1450
(600 ~ 5200)
ZSE20BF: 0x0384 ~ 0x13EC
(900 ~ 5100)
0x03F5
(1013)
0 R/W
H_1
(Setting of
OUT1
hysteresis)
Y U16
ISE20B: 0x04B0
(1200)
ZSE20B: 0x04B0
(1200)
ZSE20BF: 0x0C1C
(3100)
Setting of OUT1 hysteresis
Setting range
ISE20B: 0x03E8 ~ 0x15F4
(1000 ~ 5620)
ZSE20B: 0x03E8 ~ 0x15E0
(1000 ~ 5600)
ZSE20BF: 0x0BB8 ~ 0x1C20
(3000 ~ 7200)
0x03F6
(1014)
0 R/W
P1L(n1L)
(Setting of
OUT1 output
set value _
Lower limit of
window
comparator)
Y U16
ISE20B: 0x0898
(2200)
ZSE20B: 0x0898
(2200)
ZSE20BF: 0x0E10
(3600)
Setting of OUT1 output set value
(lower limit of window comparator)
Setting range
ISE20B: 0x0244 ~ 0x1450
(580 ~ 5200)
ZSE20B: 0x0258 ~ 0x1450
(600 ~ 5200)
ZSE20BF: 0x0384 ~ 0x13EC
(900 ~ 5100)

Related product manuals