-21-
No.PS※※-OMJ0004-E
Indication unit ( ) (available with unit conversion function)
The indication unit can be selected freely.
Setting and display resolution
MPa
0.01
Kgf/cm
2
0.1
bar
0.1
psi
1
<How to perform>
1. Press the
button three times in the measurement mode.
[ ] and current setting appears in turn.
2. Press the or button to select the indication unit
3. Press the button to enter the setting.
The measurement mode returns.
Caution
If the indication units are changed, the set value and hysteresis should be set again.