EasyManua.ls Logo

SMC Networks ISE35

SMC Networks ISE35
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-22-
No.PS※※-OMJ0004-E
Other Settings
Peak/Bottom hold value indication
The maximum (minimum) pressure from when the power is supplied to this moment is detected and updated.
In the peak/bottom indication mode, the pressure is indicated.
As the peak indication, when the
button is pressed for 1 second or longer, the maximum pressure starts
flashing and is held.
To release holding the indication of the maximum pressure, press the
button for 1 second or longer
again.
The measurement mode returns.
As the bottom indication, when the
button is pressed for 1 second or longer, the minimum pressure
starts flashing and is held.
To release holding the indication of the minimum pressure, press the
button for 1 second or longer
again.
The measurement mode returns.
If the
and
buttons are pressed simultaneously for 1 second or longer while the pressure is being
held, the maximum (minimum) value is initialized.
Zero clear
A displayed value can be adjusted to zero when the pressure to be measured is within 10%F.S. of the
pressure at the time of shipment from the factory.
(The range of 1 digit setting is different depending on the individual product difference.)
Press continuously the
and
buttons for 1 second or longer simultaneously, display is cleared as "0".
The measurement mode returns automatically.
Key lock
A wrong operation performed unintentionally such as change of set value can be
prevented.
If the button operation is performed while key lock setting is being performed,
[ ] is indicated for approx. 1 second.
<How to perform -without secret code input->
1. Keep pressing the button for 5 seconds or longer in the measurement mode.
The current setting [ ] or [ ] is indicated.
(Releasing key lock can be done in the same way.)
2. Press the
or
button to select locking or unlocking of the key.
3. Press the
button to enter the setting.