Specifications
Piping Specifications
Model
01 N01 C4H C6H
Sensor pressure receiving area: Silicon
C3602 (electroless nickel plated)
O-ring: HNBR
N7H C4L C6L N7L
—
ø1/4 inch
—
ø6 mm
—
ø4 mm
ø5/32 inch
ø1/4 inch
—
ø6 mm
—
——————
ø4 mm
ø5/32 inch
—
NPT1/8
M5 x 0.8
—
R1/8
M5 x 0.8
— —
—
One-touch fitting, Straight type
One-touch fitting, Elbow type
Sensor pressure receiving area
Piping port
Including lead wire with connector (3 cores, 2 m)
Including lead wire with connector (4 cores, 2 m)
Excluding lead wire with connector
PBT, POM, Stainless steel 304, C3604 (electroless nickel plated)
O-ring: NBR
81 g
85 g
43 g
70 g
74 g
32 g
Port size
Wetted
parts
material
Weight
71 g
75 g
33 g
73 g
77 g
35 g
75 g
79 g
37 g
73 g
77 g
35 g
75
g
79
g
37
g
Optional Part No.
When optional parts are required separately, use the following part numbers to place an order.
ZS-38-A1
ZS-38-A2
ZS-27-C
ZS-27-D
ZS-27-01
ZS-38-3L
ZS-38-4L
ZS-38-3G
ZS-38-4G
Bracket A
Bracket B
Panel mount adapter
Panel mount adapter + front protection cover
Front protection cover
Lead wire with connector
Lead wire with connector
Lead wire with connector (with connector cover)
Lead wire with connector (with connector cover)
Mounting screw (with 2 pcs. of M3 x 5L)
Mounting screw (with 2 pcs. of M3 x 5L)
Mounting screw (with 2 pcs. of M3 x 8L)
Mounting screw (with 2 pcs. of M3 x 8L)
3 cores, for 1 output, 2 m
4 cores, for 2 outputs, 2
m
3 cores, for 1 output, 2
m
4 cores, for 2 outputs, 2
m
Part no. Option Note
ZS-38-5L
ZS-38-U
ZS-38-C4H
ZS-38-C6H
ZS-38-N7H
ZS-38-C4L
ZS-38-C6L
ZS-38-N7L
ZS-38-H
Lead wire with a connector for copying
Lead wire unit with a connector for copying
One-touch fittings ø4 mm straight
One-touch fittings ø6 mm straight
One-touch fittings ø1/4 inch straight
One-touch fittings ø4 mm elbow
One-touch fittings ø6 mm elbow
One-touch fittings ø1/4 inch elbow
Operating manual CD-ROM
3 cores, copy function, 1 m
Copy function (up to 10 slaves)
O-ring, one-touch clip included
O-ring, one-touch clip included
O-ring, one-touch clip included
O-ring, one-touch clip included
O-ring, one-touch clip included
O-ring, one-touch clip included
Part no. Option Note
Note 1) If applied pressure fluctuates near the set value, set the hysteresis above the fluctuation range to prevent chattering.
Note 2) When analogue the voltage output is selected, a simultaneous selection of switch output and current output is not available.
Note 3) When analogue the current output is selected, a simultaneous selection of switch output and voltage output is not available.
Model ZSE30A (Vacuum pressure)
Rated pressure range
Regulating pressure range
Proof pressure
Setting/display resolution
Applicable fluid
Power supply voltage
Current consumption
Switch output
Repeatability
Analogue
output
Hystere-
sis
Display
Display accuracy
Indicator light
Environ-
ment
resistance
Temperature characteristics
Lead wire
Standards
0.0 to –101.0 kPa
10.0 to –105.0 kPa
500 kPa
0.1 kPa
0.6 to 5 V ±2.5% F.S. or less (with rated pressure range)
ZSE30AF (Compound pressure)
–100.0 to 100.0 kPa
–105.0 to 105.0 kPa
500 kPa
0.1 kPa
Air, non-corrosive gas, non-flammable gas
12 to 24 VDC
±10%, Ripple (p-p) 10% or less (with power supply polarity protection)
40 mA or less
NPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)
80 mA
28 V (with NPN output)
1 V or less (with load current of 80 mA)
2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)
With short circuit protection
±0.2% F.S. ±1 digit
±1% F.S. or less
Approx. 1
kΩ
±1% F.S. or less
4-digit, 7-segment, 2-colour LCD (Red and Green)
±2% F.S. ±1 digit (ambient temperature of 25 ±3°C)
Lights up when switch output is ON. OUT1: Green, OUT2: Red
IP40
Operating: 0 to 50
°C, Stored: –10 to 60°C (no freezing or condensation)
Operating/Stored: 35 to 85% RH (no condensation)
1000 VAC for 1 minute between live parts and enclosure
50 MΩ or more between live parts and enclosure (at 500 VDC Mega)
10 to 150 Hz, 1.5 mm amplitude (or 20 m/s
2
acceleration), in X, Y, Z directions, for 2 hours each (Non-energized)
100 m/s
2
in X, Y, Z directions, 3 times each (non-energised)
±2% F.S. (based on 25°C)
CE Marking, UL/CSA, RoHS compliance
Variable (0 or above)
Note 1)
ISE30A (Positive pressure)
–0.100 to 1.000 MPa
–0.105 to 1.050 MPa
1.5 MPa
0.001 MPa
Maximum load current
Maximum applied voltage
Residual voltage
Response time
Short circuit protection
Voltage
output
Hysteresis mode
Window comparator mode
Enclosure
Operating temperature range
Operating humidity range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
1 to 5V ±2.5% F.S. or less (with rated pressure range)
2.4 to 20 mA ±2.5% F.S. or less (with rated pressure range)
4 to 20 mA ±2.5% F.S. or less (with rated pressure range)
Output voltage
Linearity
Output impedance
Current
output
Output current
Linearity
Load impedance
Maximum load impedance: 300
Ω with power supply voltage of 12 V; 600 Ω with power supply voltage of 24 V
Minimum load impedance: 50
Ω
Oilproof heavy-duty vinyl cable, 3 cores ø3.5, 2
m
4 cores Conductor area: 0.15 mm
2
(AWG26), Insulator O.D.: 1.0 mm
Note 2)
Note 3)
Series ZSE30A
(
F
)
/ISE30A
Copies the settings of the master sensor to the slave sensors.
Calculates and enters rough set values automatically from the actual operating conditions.
Evens out deviations in the displayed value.
Can retain the maximum pressure value displayed during measurement.
Can retain the minimum pressure value displayed during measurement.
The key board can be locked to prevent any incorrect function of the switch.
The pressure display can be set at zero when the pressure is open to the atmosphere.
Prevents possible malfunction due to sudden fluctuations in the primary pressure by adjusting the response time.
Can convert the display value.
Reduces power consumption.
Converts display resolution from the normal value of 1/1000 to 1/100.
It reduces the monitor to flicker.
Converts the unit between kPa and MPa.
Displays unit being used (only kPa and MPa).
Lights up when switch output (OUT1) is turned ON.
ON/OFF set value.
mode.
value.
ON/OFF set value.
display mode.
Lights up when switch output (OUT2) is turned ON.
different display settings are available.