ACM1_TAU_UserManual_En
Page 11 of 35
SME s.p.a. Via della Tecnica 40 Z.I.
36071 ARZIGNANO (VI) ITALY
Phone +39 0444 470511 - Fax +39 0444 451803
info@grupposme.com - www.grupposme.com
2.3.3 Interfaces
Serial Communication: RS-232
CAN:
Protocol: CAN Open
Physical layer: ISO11898-2
Baud rates: 1Mbps, 800kbps, 500kbps, 250kbps, 125kbps, 50kbps
Lin Bus
2.3.4 EMC
EN12895 (Industrial Trucks – Electromagnetic Compatibility)
2.3.5 Safety
EN1175-1 (Safety of Industrial Trucks – Electrical Requirements)
The vehicle OEM takes full responsibility of the regulatory compliance of the
vehicle system with the controller installed.
2.4 Operating Environment Specifications
Storage ambient temperature range: -40°C ÷ +70°C
Operating ambient temperature range: -40°C ÷ +55°C
Heatsink operating temperature range: -40°C ÷ +95°C
With linear derating: +80°C ÷ +95°C
Protection Level: IP65
Vibration: Tested under conditions suggested by EN60068-2-6 [5g, 10÷500Hz, 3 axes]
Shock & Bump: Tested under conditions suggested by EN60068-2-27
Cold & Heat: Tested under conditions suggested by EN60068-2-1
Mechanical size: 210 x 145 x 91 [mm]
Weight: 3 kg