2.3.3 Interfaces
Serial Communication: RS-232
CAN:
Protocol: CAN Open
Physical layer: ISO11898-2
Baud rates: 1Mbps, 800kbps, 500kbps, 250kbps, 125kbps, 50kbps
Lin Bus
2.3.4 EMC
EN12895 (Industrial Trucks Electromagnetic Compatibility)
2.3.5 Safety
EN1175-1 (Safety of Industrial Trucks Electrical Requirements)
The vehicle OEM takes full responsibility of the regulatory compliance of the
vehicle system with the controller installed.
2.4 Operating Environment Specifications
Storage ambient temperature range: -40°C ÷ +70°C
Operating ambient temperature range: -40°C ÷ +55°C
Heatsink operating temperature range: -40°C ÷ +95°C
With linear derating: +8C ÷ +95°C
Protection Level: IP65
Vibration: Tested under conditions suggested by EN60068-2-6 [5g, 10÷500Hz, 3 axes]
Shock & Bump: Tested under conditions suggested by EN60068-2-27
Cold & Heat: Tested under conditions suggested by EN60068-2-1
Mechanical size: 210 x 145 x 91 [mm]
Weight: 3 kg