14
Stop&Go function
This function brakes all the hob’s cooking activity temporarily and allows restarting with the same
settings.
Startup/stop the pause function :
Action Control panel Display
Engage pause press [ II ] key displays [ II ] in the
during 2s heating zone displays
Stop the pause press [ II ] key pause control light is
during 2s blinking
press an other touch or pause control light is off
slide on the “SLIDER“
Recall Function
After switching off the hob (0/I), it is possible to recall the last settings.
cooking stages of all cooking zones (power)
minutes and seconds of programmed cooking zone-related timers
Keep warm function
The recall procedure is following:
Press the key [0/I]
Then simultaneously press the 2 zones back in less than 6 seconds.
The previous settings are again active.
« Keep warm » Function
This function allows to reach and maintain automatically a temperature of 70°C.
This will avoid liquids overflowing and fast burning at the bottom of the pan.
To engage, to start the function « Keep warm » :
Action Control panel Display
To engage press the slider between [ U ]
[ 0 ] and [ 1 ]
To stop slide on the “SLIDER“ [ 0 ] to [ 9 ] or [ H ]
Control panel Locking
To avoid modification of the setting of the cooking zones , in particular during cleaning, the
control panel can be locked (with exception to the On/Off key [ 0/I ]).
Lock :
Action Control panel Display
Start press on key [ 0/I ] [ 0 ] or [ H ] on displays
Hob locking press on key [ ll ] and keep your
finger on this key, with your other
finger press 3 times key [ ] [ L ] on displays
Unlock :
Action Control panel Display
Start press on key [ 0/I ] [ L ] on displays
In the 5 seconds after start:
Unlocking the hob press on key [ ll ] and keep your
finger on this key, with your other
finger press 3 times key [
] [ 0 ] or [ H ] on displays